You are here: Home > Heater Overloads > Square D Heater Overloads > Type A Square D Heater Overload
Sort By:
Page of 1
A.49 SQUARE D THERMAL HEATER OVERLOAD A.49 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D - A.49 : THERMAL OVERLOAD HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.43 TO 0.47 AMPERE
(1 THERMAL UNIT)
0.41 TO 0.45 AMPERE (2 THERMAL UNITS)
0.4 TO 0.41 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.49 (R) SQUARE D THERMAL HEATER OVERLOAD A.49 (R) SQUARE D THERMAL HEATER OVERLOAD


(REFURBISHED / USED CLEANED & TESTED)

SQUARE D A.49 : THERMAL OVERLOAD HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.43 TO 0.47 AMPERE (1 THERMAL UNIT)
0.41 TO 0.45 AMPERE (2 THERMAL UNITS)
0.4 TO 0.41 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER / MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.54 SQUARE D THERMAL HEATER A.54 SQUARE D THERMAL HEATER

SQUARE D A.54 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.48 TO 0.51 AMPERE (1 THERMAL UNIT)
0.46 TO 0.50 AMPERE (2 THERMAL UNITS)
0.42 TO 0.46 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.54 (R) SQUARE D THERMAL HEATER A.54 (R) SQUARE D THERMAL HEATER

(REFURBISHED CLEANED & TESTED)

SQUARE D A.54 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.48 TO 0.51 AMPERE (1 THERMAL UNIT)
0.46 TO 0.50 AMPERE (2 THERMAL UNITS)
0.42 TO 0.46 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.59 SQUARE D THERMAL HEATER A.59 SQUARE D THERMAL HEATER

SQUARE D A.59 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.52 TO 0.56 AMPERE (1 THERMAL UNIT)
0.51 TO 0.55 AMPERE (2 THERMAL UNITS)
0.47 TO 0.51 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.59 (R) SQUARE D THERMAL HEATER A.59 (R) SQUARE D THERMAL HEATER

(REFURBISHED CLEANED & TESTED)

SQUARE D A.59 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.52 TO 0.56 AMPERE (1 THERMAL UNIT)
0.51 TO 0.55 AMPERE (2 THERMAL UNITS)
0.47 TO 0.51 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.65 SQUARE D THERMAL HEATER OVERLOAD A.65 SQUARE D THERMAL HEATER OVERLOAD

SQUARE D A.65 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.57 TO 0.64 AMPERE (1 THERMAL UNIT)
0.56 TO 0.62 AMPERE (2 THERMAL UNITS)
0.52 TO 0.57 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.65 (R) SQUARE D THERMAL HEATER OVERLOAD A.65 (R) SQUARE D THERMAL HEATER OVERLOAD

(REFURBISHED CLEANED & TESTED)

SQUARE D A.65 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.57 TO 0.64 AMPERE (1 THERMAL UNIT)
0.56 TO 0.62 AMPERE (2 THERMAL UNITS)
0.52 TO 0.57 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.78 SQUARE D THERMAL HEATER OVERLOAD A.78 SQUARE D THERMAL HEATER OVERLOAD

SQUARE D A.78 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.7 TO 0.76 AMPERE (1 THERMAL UNIT)
0.68 TO 0.72 AMPERE (2 THERMAL UNITS)
0.63 TO 0.67 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.86 SQUARE D THERMAL HEATER OVERLOAD A.86 SQUARE D THERMAL HEATER OVERLOAD

SQUARE D A.86 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.77 TO 0.84 AMPERE (1 THERMAL UNIT)
0.73 TO 0.81 AMPERE (2 THERMAL UNITS)
0.68 TO 0.75 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.86 (R) SQUARE D THERMAL HEATER OVERLOAD A.86 (R) SQUARE D THERMAL HEATER OVERLOAD

(REFURBISHED CLEANED & TESTED)

SQUARE D A.86 : THERMALHEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.77 TO 0.84 AMPERE (1 THERMAL UNIT)
0.73 TO 0.81 AMPERE (2 THERMAL UNITS)
0.68 TO 0.75 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A.95 SQUARE D THERMAL HEATER OVERLOAD A.95 SQUARE D THERMAL HEATER OVERLOAD

SQUARE D A.95 : THERMAL HEATER OVERLOAD

Technical Description:

CLASS 20
STANDARD TRIP
MOTOR FLA 0.85 TO 0.91 AMPERE (1 THERMAL UNIT)
0.82 TO 0.88 AMPERE (2 THERMAL UNITS)
0.76 TO 0.8 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A1.16 SQUARE D HEATER OVERLOAD A1.16 SQUARE D HEATER OVERLOAD

SQUARE D A1.16 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 1.02 TO 1.15 AMPERE (1 THERMAL UNIT)
0.98 TO 1.08 AMPERE (2 THERMAL UNITS)
0.9 TO 1.02 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A1.16 (R) SQUARE D THERMAL HEATER OVERLOAD A1.16 (R) SQUARE D THERMAL HEATER OVERLOAD


(REFURBISHED CLEANED & TESTED)

SQUARE D A1.16 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20,
STANDARD TRIP;
MOTOR FLA 1.02 TO 1.15 AMPERE (1 THERMAL UNIT)
0.98 TO 1.08 AMPERE (2 THERMAL UNITS)
0.9 TO 1.02 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A1.25 SQUARE D THERMAL HEATER OVERLOAD A1.25 SQUARE D THERMAL HEATER OVERLOAD

Square D A1.25 Overload Heater

Amp Range:

1.13 - 1.20 (Single Phase)
1.06 - 1.13 (2 Phase)
0.99 - 1.07 (3 Phase)

A1.39 SQUARE D THERMAL UNIT A1.39 SQUARE D THERMAL UNIT


SQUARE D A1.39 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 1.24 TO 1.37 AMPERE (1 THERMAL UNIT)
1.19 TO 1.32 AMPERE (2 THERMAL UNIT)
1.10 TO 1.21 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A1.54 SQUARE D THERMAL UNIT A1.54 SQUARE D THERMAL UNIT


SQUARE D A1.54 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 1.38 TO 1.45 AMPERE (1 THERMAL UNIT)
1.33 TO 1.4 AMPERE (2 THERMAL UNIT)
1.22 TO 1.29 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A1.63 SQUARE D THERMAL UNIT A1.63 SQUARE D THERMAL UNIT

SQUARE D A1.63 : THERMAL UNIT

Technical Description:

CLASS 20
STANDARD TRIP
MOTOR FLA 1.46 TO 1.56 AMPERE (1 THERMAL UNIT)
1.41 TO 1.48 AMPERE (2 THERMAL UNIT)
1.3 TO 1.37 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY


A1.75 SQUARE D THERMAL UNIT A1.75 SQUARE D THERMAL UNIT


SQUARE D A1.75 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 1.57 TO 1.67 AMPERE (1 THERMAL UNIT)
1.49 TO 1.6 AMPERE (2 THERMAL UNIT)
1.38 TO 1.48 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A1.99 SQUARE D THERMAL UNIT A1.99 SQUARE D THERMAL UNIT


SQUARE D A1.99 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 1.78 TO 1.92 AMPERE (1 THERMAL UNIT)
1.73 TO 1.84 AMPERE (2 THERMAL UNIT)
1.59 TO 1.72 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER,
SEPARATELY MOUNTED OVERLOAD RELAY

A11.0 A11.0

Square D A11.0 Overload Heater

Amp Range:

7.19 TO 8.24 MAX

A11.0 (R) A11.0 (R)


(REFURBISHED)

Square D A11.0 Overload Heater

Amp Range:

7.19 TO 8.24 MAX

A13.2 SQUARE D THERMAL UNIT A13.2 SQUARE D THERMAL UNIT


SQUARE D A13.2 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 8.99 TO 9.67 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A13.2 (R) SQUARE D THERMAL UNIT A13.2 (R) SQUARE D THERMAL UNIT

(REFURBISHED / CLEANED & TESTED)

SQUARE D A13.2 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 8.99 TO 9.67 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A14.1 SQUARE D THERMAL UNIT A14.1 SQUARE D THERMAL UNIT


SQUARE D A14.1 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 9.68 TO 9.99 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A14.8 SQUARE D THERMAL UNIT A14.8 SQUARE D THERMAL UNIT


SQUARE D A14.8 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 9.96 TO 10.8 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A19.8 SQUARE THERMAL HEATER A19.8 SQUARE THERMAL HEATER


SQUARE D A19.8 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 13.2 TO 13.9 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A2.15 SQUARE D THERMAL HEATER A2.15 SQUARE D THERMAL HEATER


SQUARE D A2.15 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 1.93 TO 2.09 AMPERE (1 THERMAL UNIT)
1.85 TO 2 AMPERE (2 THERMAL UNIT)
1.73 TO 1.85 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A2.15 (R) SQUARE THERMAL HEATER A2.15 (R) SQUARE THERMAL HEATER


(REFURBISHED CLEANED & TESTED)

SQUARE D A2.15 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 1.93 TO 2.09 AMPERE (1 THERMAL UNIT)
1.85 TO 2 AMPERE (2 THERMAL UNIT)
1.73 TO 1.85 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A2.31 (R) SQUARE D THERMAL HEATER A2.31 (R) SQUARE D THERMAL HEATER


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A2.31 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 2.10 TO 2.31 AMPERE (1 THERMAL UNIT)
2.01 TO 2.22 AMPERE (2 THERMAL UNIT)
1.86 TO 2.05 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY



A2.57 SQUARE D THERMAL HEATER A2.57 SQUARE D THERMAL HEATER


SQUARE D A2.57 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 2.32 TO 2.56 AMPERE (1 THERMAL UNIT)
2.23 TO 2.45 AMPERE (2 THERMAL UNIT)
2.06 TO 2.29 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A2.57 (R) SQUARE D THERMAL HEATER A2.57 (R) SQUARE D THERMAL HEATER


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A2.57 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 2.32 TO 2.56 AMPERE (1 THERMAL UNIT)
2.23 TO 2.45 AMPERE (2 THERMAL UNIT)
2.06 TO 2.29 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A2.81 SQUARE D THERMAL HEATER A2.81 SQUARE D THERMAL HEATER


SQUARE D A2.81 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 2.57 TO 2.92 AMPERE (1 THERMAL UNIT)
2.46 TO 2.82 AMPERE (2 THERMAL UNIT)
2.3 TO 2.62 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A2.81 (R) SQUARE D THERMAL HEATER A2.81 (R) SQUARE D THERMAL HEATER


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A2.81 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 2.57 TO 2.92 AMPERE (1 THERMAL UNIT)
2.46 TO 2.82 AMPERE (2 THERMAL UNIT)
2.3 TO 2.62 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A21.3 SQUARE D THERMAL HEATER A21.3 SQUARE D THERMAL HEATER

SQUARE D A21.3 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 14 TO 15 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A25.2 SQUARE D THERMAL HEATER A25.2 SQUARE D THERMAL HEATER

SQUARE D A25.2 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 15.1 TO 16 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A3.61 SQUASRE D THERMAL HEATER A3.61 SQUASRE D THERMAL HEATER


SQUARE D A3.61 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 2.93 TO 3.16 AMPERE (1 THERMAL UNIT)
2.83 TO 3.08 AMPERE (2 THERMAL UNIT)
2.63 TO 2.84 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A3.61 (R) SQUARE D THERMAL HEATER A3.61 (R) SQUARE D THERMAL HEATER


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A3.61 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 2.93 TO 3.16 AMPERE (1 THERMAL UNIT)
2.83 TO 3.08 AMPERE (2 THERMAL UNIT)
2.63 TO 2.84 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A3.95 SQUARE THERMAL HEATER A3.95 SQUARE THERMAL HEATER


SQUARE D A3.95 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 3.17 TO 3.48 AMPERE (1 THERMAL UNIT)
3.09 TO 3.39 AMPERE (2 THERMAL UNIT)
2.85 TO 3.1 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A3.95 (R) SQUARE THERMAL HEATER A3.95 (R) SQUARE THERMAL HEATER


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A3.95 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 3.17 TO 3.48 AMPERE (1 THERMAL UNIT)
3.09 TO 3.39 AMPERE (2 THERMAL UNIT)
2.85 TO 3.1 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A4.32 SQUARE D THERMAL HEATER A4.32 SQUARE D THERMAL HEATER


SQUARE D A4.32 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 3.49 TO 3.83 AMPERE (1 THERMAL UNIT)
3.4 TO 3.75 AMPERE (2 THERMAL UNIT)
3.11 TO 3.46 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A4.32 (R) SQUARE D THERMAL HEATER A4.32 (R) SQUARE D THERMAL HEATER


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A4.32 : THERMAL HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 3.49 TO 3.83 AMPERE (1 THERMAL UNIT)
3.4 TO 3.75 AMPERE (2 THERMAL UNIT)
3.11 TO 3.46 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A4.79 SQUARE D HEATER OVERLOAD A4.79 SQUARE D HEATER OVERLOAD


SQUARE D A4.79 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 3.84 TO 4.24 AMPERE (1 THERMAL UNIT)
3.76 TO 4.16 AMPERE (2 THERMAL UNIT)
3.47 TO 3.85 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A4.79 (R) SQUARE D THERMAL HEATER OVERLOAD A4.79 (R) SQUARE D THERMAL HEATER OVERLOAD


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A4.79 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 3.84 TO 4.24 AMPERE (1 THERMAL UNIT)
3.76 TO 4.16 AMPERE (2 THERMAL UNIT)
3.47 TO 3.85 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A5.30 SQUARE D THERMAL HEATER OVERLOAD A5.30 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A5.30 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 4.25 TO 4.62 AMPERE (1 THERMAL UNIT)
4.17 TO 4.51 AMPERE (2 THERMAL UNIT)
3.86 TO 4.16 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A5.30 (R) SQUARE THERMAL OVERLOAD HEATER A5.30 (R) SQUARE THERMAL OVERLOAD HEATER


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A5.30 : THERMAL OVERLOAD HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 4.25 TO 4.62 AMPERE (1 THERMAL UNIT)
4.17 TO 4.51 AMPERE (2 THERMAL UNIT)
3.86 TO 4.16 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A5.78 SQUARE D THERMAL HEATER OVERLOAD A5.78 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A5.78 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 4.63 TO 4.92 AMPERE (1 THERMAL UNIT)
4.52 TO 4.83 AMPERE (2 THERMAL UNIT)
4.17 TO 4.46 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A5.78 (R) SQUARE D THERMAL HEATER OVERLOAD A5.78 (R) SQUARE D THERMAL HEATER OVERLOAD


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A5.78 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 4.63 TO 4.92 AMPERE (1 THERMAL UNIT)
4.52 TO 4.83 AMPERE (2 THERMAL UNIT)
4.17 TO 4.46 AMPERE (3 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A6.99 (R) SQUARE D THERMAL HEATER OVERLOAD A6.99 (R) SQUARE D THERMAL HEATER OVERLOAD


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A6.99 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 5.62 TO 5.85 AMPERE (1 THERMAL UNIT)
5.5 TO 5.67 AMPERE (2 THERMAL UNITS)
5.09 TO 5.35 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A8.38 SQUARE D THERMAL HEATER OVERLOAD A8.38 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A8.38 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 6.37 TO 6.99 AMPERE (1 THERMAL UNIT)
6.17 TO 6.75 AMPERE (2 THERMAL UNITS)
5.83 TO 6.34 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A8.38 (R) SQUARE D THERMAL OVERLOAD HEATER A8.38 (R) SQUARE D THERMAL OVERLOAD HEATER


(REFURBISHED / USED, CLEANED & TESTED)

SQUARE D A8.38 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 6.37 TO 6.99 AMPERE (1 THERMAL UNIT)
6.17 TO 6.75 AMPERE (2 THERMAL UNITS)
5.83 TO 6.34 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A9.25 SQUARE D THERMAL OVERLOAD HEATER A9.25 SQUARE D THERMAL OVERLOAD HEATER


SQUARE D A9.25 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 7.00 TO 7.67 AMPERE (1 THERMAL UNIT)
6.76 TO 7 AMPERE (2 THERMAL UNITS)
6.35 TO 6.95 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A1.02 SQUARE D THERMAL UNIT A1.02 SQUARE D THERMAL UNIT

SQUARE D A1.02 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 0.92 TO 1.01 AMPERE (1 THERMAL UNIT)
0.89 TO 0.97 AMPERE (2 THERMAL UNITS)
0.81 TO 0.89 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A16.2 SQUARE D THERMAL HEATER OVERLOAD A16.2 SQUARE D THERMAL HEATER OVERLOAD

SQUARE D A16.2 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 10.9 TO 12.1 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A6.99 SQUARE THERMAL HEATER OVERLOAD A6.99 SQUARE THERMAL HEATER OVERLOAD

SQUARE D A6.99 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 5.62 TO 5.85 AMPERE (1 THERMAL UNIT)
5.5 TO 5.67 AMPERE (2 THERMAL UNITS)
5.09 TO 5.35 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A7.65 SQUARE THERMAL HEATER OVERLOAD A7.65 SQUARE THERMAL HEATER OVERLOAD

SQUARE D A7.65 : THERMAL UNIT

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 5.86 TO 6.36 AMPERE (1 THERMAL UNIT)
5.68 TO 6.16 AMPERE (2 THERMAL UNITS)
5.36 TO 5.82 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A9.85 SQUARE D THERMAL HEATER OVERLOAD A9.85 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A9.85 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 7.19 TO 7.8 AMPERE (1 THERMAL UNIT)
6.9 TO 7 AMPERE (2 THERMAL UNITS)
6.44 TO 6.79 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A1.86 SQUARE D THERMAL HEATER OVERLOAD A1.86 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A1.86 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 1.68 TO 1.77 AMPERE (1 THERMAL UNIT)
1.61 TO 1.72 AMPERE (2 THERMAL UNITS)
1.49 TO 1.58 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A11.9 SQUARE D THERMAL HEATER OVERLOAD A11.9 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A11.9 : THERMAL OVERLOAD HEATER

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 8.16 TO 8.98 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A17.9 SQUARE D THERMAL HEATER OVERLOAD A17.9 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A17.9 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 12.2 TO 13.1 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A2.31 SQUARE D THERMAL HEATER OVERLOAD A2.31 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A2.31 : SQUARE D THERMAL HEATER OVERLOAD

Technical Description:

CLASS 20
STANDARD TRIP
MOTOR FLA 2.10 TO 2.31 AMPERE (1 THERMAL UNIT)
2.01 TO 2.22 AMPERE (2 THERMAL UNITS)
1.86 TO 2.05 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A27.1 SQUARE D THERMAL HEATER OVERLOAD A27.1 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A27.1 : THERMAL HEATER OVERLOAD

Technical Description:

CLASS 20
STANDARD TRIP
MOTOR FLA 15.9 TO 18.4 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A29.5 SQUARE D THERMAL HEATER OVERLOAD A29.5 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A29.5 : THERMAL HEATER OVERLOAD

Technical Description:

CLASS 20
STANDARD TRIP
MOTOR FLA 18.9 TO 20.5 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A31.9 SQUARE D THERMAL HEATER OVERLOAD A31.9 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A31.9 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 20.6 TO 21.5 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A33.8 SQUARE D THERMAL HEATER OVERLOAD A33.8 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A33.8 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 21.6 TO 23.9 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A35.9 A35.9

SQUARE D A 35.9 THERMAL UNIT

A40.0 SQUARE D THERMAL HEATER OVERLOAD A40.0 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A40.0 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 26.9 TO 28.2 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A42.3 SQUARE D THERMAL HEATER OVERLOAD A42.3 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A42.3 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 28.3 TO 29.8 AMPERE (1 THERMAL UNIT)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY

A44.7 A44.7

SQUARE D A44.7 THERMAL UNIT

A48.0 A48.0

SQUARE D THERMAL UNIT

A6.20 SQUARE D THERMAL HEATER OVERLOAD A6.20 SQUARE D THERMAL HEATER OVERLOAD


SQUARE D A6.20 : THERMAL HEATER OVERLOAD

Technical Description:
CLASS 20
STANDARD TRIP
MOTOR FLA 4.93 TO 5.61 AMPERE (1 THERMAL UNIT)
4.84 TO 5.49 AMPERE (2 THERMAL UNITS)
4.47 TO 5.08 AMPERE (3 THERMAL UNITS)
PLUG IN MOUNTING
USED ON AC/DC MAGNETIC STARTER, MANUAL STARTER
SEPARATELY MOUNTED OVERLOAD RELAY